ARI -HC-30 Hand-Held EtCO2+SpO2 monitor

SKU: IMPORT & SUPPLY- 30days time Category:

Description

Clinical significance

  1. Confirm the position and patency of trachea cannula
  2. Monitor the circulatory function / Evaluate the effectiveness of CPR
  3. Transport use
  4. Monitor the ventilation function
  5. Monitor the supersession function / Early diagnose malignant hyperthermia
  6. Find the fault of ventilator and Anaesthesia machine
  7. Auxiliary diagnosis of pulmonary embolism
  8. Good relativity with PaCO2 to reduce the frequency of blood gas analysis and palliate sufferings of patients
  9. Feature
  10. Slim shape, thickness is only 24mm,one-handed performance
  11. Easy operation with 4.0″ touch LCD display, screen lock function
  12. 16G mass storage, can store more than 100000 patient’s information and data
  13. Continuous real time when power off
  14. Patient’s information &data, tendency chart automatic storage when power off
  15. Auto brightness adjustment according to the environmental brightness changes
  16. Support 7-20 hours continuous work

III. Characteristic

  1. Read the data directly via PC, no need extra software
  2. Multifunctional USB port: storage, data output, fast charging
  3. Product Details

1.Patient data return visit

Review the patient’s information and measured data, tendency

2.Various mounting solution

Pole stand

Wall mounting rack

Desktop bracket

3.Remote network solution

WIFI, Bluetooth, APP, Telemedcine, Cloud service

4.Professional ETCO2 Solutions

Degermed, xerantic, integrated-sampling tube, fast plug in&out

AwRR 160/min

Support gas compensation (O2,N2O and other-anesthetic-gases

Built-in,side-stream,EtCO2 module, main-stream is optional

  1. Technical Specifications
  2. Size:148(L)*76(W)*24(H)
  3. Weight:250g
  4. Touch LCD display:4″ 800*600 dpi
  5. Internal memory:16G SD card
  6. Storage temperature:-20 °C – 55 °C
  7. Usage temperature:0 – 40 °C
  8. Humidity:15%-95%
  9. Power:5V DC,USB
  10. Charger:100-240V AC,50/60HZ
  11. Lithium battery:3.7V DC 3500mah
  12. Continuous working time:7 hour (CO2+SPO2)
  13. Out put:USB, BLE, WLAN, SPO2
  14. Range:0%-100%
  15. Precision:±2% ( 70%-100% Adult/Paed ),±3% ( 70%-100% Neonate )
  16. Resolution: ±1%

PR

Range:30-250BPM

Precision:±1BPM

SPO2

Range:0%-100%

Precision:

±2% (70%-100% Adult/Paed)

±3% (70%-100% Neonate)

Resolution:±1%

ETCO2
Range: 0-20% 0-150mmhg
Precision:

±2% 0-40mmhg

±5470mmhg

±8% 71-100mmhg

±10% 101-150mmhg
Sampling rate:50±10ml/min

AwRR
Range:3-160 rmp/min
Precision:±1rpm
Gas compensation:O2, N2O and anesthetic
Pressure compensation: automatic 400-800 mmhg
Sampling tube: degermed, xerantic, intergrated
, fast plug in & out