Description
Usage
Orthopedics: osteopathy, displaces, nailing.
Surgery: removing foreign body, cardiac catheter, implanting pace maker, interventional therapy, partial radiography, local photography, and other work.
- Features
- New integrated design, compact appearance, convenient operation.
- Unique hand-held remote controller, more convenient operation
- Graphical colorfully LCD touch screen console interface, convenient operation, fashionable design.
- High-quality combined HF-HV X-ray generator, greatly reducing the X-ray irradiation.
- Toshiba image intensifier is employed, stable and reliable in quality, high-definition image and display system.
- With the perspective KV, MA auto8matic tracking feature, the image brightness and definition are automatically set at optimal function.
- Integrated digital acquisition and processing system make the operation more convenient.
III. Configuration
1, New (with electric auxiliary support arm) C-arm main rack 1 set
2, High-frequency high-voltage X-ray generator and high-frequency inverter power supply
(5KW,40KHZ,120KV) 1 set
3, Toshiba 9-inch image intensifier 1 set
4, Megapixel ultra-low-light digital cameras 1 set
5, Integrated digital acquisition and processing system 1 set
6, High-thickness grids 1 set
7, Electric adjustable collimator 1 set
8, 24-inch LCD monitor, resolution:1920*1080 1 set
9, Unique hand-held remote controller 1 set
- Technical Specifications
PARAMETER | SPECIFICATION | ||
Fluoroscopic
Capacity |
Max rated capacity | Tube Current 4mA, | |
Tube Voltage 120kV | |||
Automatic Fluoroscopy | Tube Voltage:40kV~120kV Adjust Automatically | ||
Tube Current | 0.3mA~4mA set manually | ||
Manual Fluoroscopy | Continuous Tube Voltage:40kV~120kV | ||
Continuous Tube Current | 0.3mA~4mA | ||
Pulse Fluoroscopy | Continuous Tube Voltage 40kV~120kV | ||
Continuous Tube Current | 0.3mA~30mA | ||
Photography Capacity | Max rated capacity | 5 KW | |
Tube Voltage and Current Combination
|
40kV~49kV 1 ~180 mAs | ||
50kV~59kV 1 ~140 mAs | |||
60kV~69kV 1 ~125 mAs | |||
70kV~79kV 1 ~110 mAs | |||
80kV~89kV 1 ~100 mAs | |||
90kV~99kV 1 ~80 mAs | |||
100kV~109kV 1 ~63 mAs | |||
110kV~120kV 1 ~50 mAs | |||
Plateholder Size | 200mm×250mm(8″×10″) or
250mm×300m(10″×12″) |
||
X-ray Tube | X-ray Tube Special for High Frequency | ||
Fixed anode Dual focus | large focus: 1.5, small focus: 0.3 (Advantage) | ||
Inverter Frequency: | 40KHz | ||
Thermal capacity: | 35KJ (47KHU) | ||
Video System | Image Intensifier | Image Intensifier made by TOSHIBA (9″,6″,4.5″) | |
CCD Vidicon | Ultralow light megapixel CCD camera imported from Japan | ||
Monitor | 23inch Horizontal 1280 lines and vertical 1024 lines, | ||
Bandwidth : | 48MHz, Image/sec : 75
grayscale: ≥ 11 Line pairs resolution: ≥ 1.2 LP / mm |
||
Integrated digital acquisition and processing system | Registration: registration, medical records, Worklist
Collection: Start collection; prepare video, reset, horizontal mirror, vertical mirror, window adjustment, magnifying glass, negative image Open silhouette, edge enhancement, recursive noise reduction Processing; four windows, nine windows, sharpening, horizontal mirror, vertical mirror, text annotation, length measurement report: save, preview, expert template Dicom features: Dicom browsing, web service |
||
Structure | Directive wheel | ±90°revolution can freely change the moving direction of the unit | |
Ascending & Descending Range of Pillar | ≥400mm | ||
C-arm | Forward and Backward Movement: 200mm | ||
Revolution around Horizontal Axis | ±180° | ||
Revolution around Vertical Axis | ±15°( Advantage), better than others’ ±12.5°, easier to take special positions radiography) | ||
Slip on orbit | 120°(+90°~ 30°) | ||
Frame monitor rotation | ≥ 300 ° | ||