Description
Features
- Professional EMG/EP operation platform and perfect test projects, complete each test in the shortest time.
 - Perfect case report data and graph creating system.
 - Special database management system.
 - Select test part with Neuro and muscle navigation system and projects selecting system fleetly and conveniently.
 - Powerful normal value system, contrast with normal data automatically.
 - Flexible software design, configure systems according to requirements.
 - High-speed data collection, electromagnetic interference suppression capability for using high strength and light quality metal enclosure.
 - Simple and convenient operation panel.
 - Good Electrostatic and electromagnetic interference suppression capability for using high strength and light quality metal enclosure.
 - Selectable 1-4 channel input mode meets multi-working modes in clinical EMG test.
 - High-speed collect and process data with parallel processing technology, display data with graph.
 
Functions
General electromyogram (EMG),Sensory nerve conductor velocity (SCS),motor nerve conductor velocity (MCS), Fwave, HRe-flex, Blink Reflex, Repetitive nerve stimulation (RNS), Brainstem auditory evoked potential (BAEP),Visual evoked potential (VEP),Somatosensory evoked potentials(SEP)
Technical Specifications
| PARAMETER | SPECIFICATION | 
| Computer part | |
| CPU | Intel Pentium III (more than 800MHz) | 
| EMS memory | More than 256M | 
| HD | More than 40G | 
| CD driver | CD-ROM or higher configuration | 
| I/O interface | More than USB2.0 interfaces | 
| Operating system | Windows 7,vista,XP 62bit,32bit | 
| Laser printer | Yes | 
| Main system part | |
| A/D conversion resolution | 16Bit | 
| Sampling ratio | 200kHz | 
| Analysis time | 5-5000ms | 
| Amplifier part | |
| Channel | 4 | 
| Sensitivity | 0.05µV-20mV/Grid | 
| CMRR | ≥100dB | 
| Filter frequency | Low-pass:1Hz~3000Hz (-3dB) | 
| High-pass:10Hz~20000Hz(-3dB) | |
| Gain amplifies | 25 times~400000 times | 
| Stimulator part | |
| Constant current | 0.2-100mA | 
| Pulse width | 50-1000µS | 
| Stimulation Frequency | 1Hz~5Hz | 
| Stimulation type | Single or continuous stimulation | 
| Protection | Short circuit and overloading protection | 
| Auditory stimulator | |
| Stimulation waveform | 40Hz short, Sound stim | 
| Stimulation polarity | Non-dense wave, dense wave and alternant wave | 
| Sound intensity | 40-120dB (5dB per level) | 
| Frequency of 40Hz carrier wave | 500-8000Hz | 
| Visual stimulator | |
| Adopts CRT display whole size | Not less than 200mmx200mm | 
| Mode | Tessellation, horizontal bar and vertical bar | 
| Stimulation view | All-view, half-view and quarter-view | 
| Resolution | 3×4,6×8,12×16 ,24×32,48×64 | 
| Flash stimulator | All quench, left light, right light, L&R light | 